Consent Framework
Consent artefacts — the signed, auditable permissions that gate every byte of health data.
Nothing moves in ABDM without a consent artefact: a digitally signed document, issued by the patient's consent manager, describing exactly what data may be shared, with whom, for what purpose, and until when.
Anatomy of a consent artefact
{
"consentDetail": {
"consentId": "a1b2c3d4-...",
"patient": { "id": "sunita.sharma@abdm" },
"purpose": { "code": "CAREMGT", "text": "Care Management" },
"hiu": { "id": "IN0510000456" },
"hip": { "id": "IN0410000123" },
"careContexts": [
{ "patientReference": "MRN-2024-0042", "careContextReference": "OPD-2025-01-15" }
],
"hiTypes": ["Prescription", "DiagnosticReport", "DischargeSummary"],
"permission": {
"accessMode": "VIEW",
"dateRange": { "from": "2024-01-01T00:00:00Z", "to": "2025-01-15T00:00:00Z" },
"dataEraseAt": "2025-07-15T00:00:00Z",
"frequency": { "unit": "HOUR", "value": 1, "repeats": 0 }
}
},
"signature": "..."
}Key fields:
purpose— a coded reason (care management, break-the-glass, insurance claims, self-requested, etc.).hiTypes— the record categories covered (see below).permission.dateRange— the clinical period of records covered, not the validity of the consent.permission.dataEraseAt— when the HIU must delete fetched data.careContexts— the specific episodes covered. A grant may narrow the request to particular contexts.
Health information types
The standard hiTypes include:
OPConsultation · Prescription · DischargeSummary · DiagnosticReport ·
ImmunizationRecord · HealthDocumentRecord · WellnessRecord ·
Invoice (newer additions appear over time)
Lifecycle
stateDiagram-v2 [*] --> REQUESTED: HIU initiates REQUESTED --> GRANTED: patient approves REQUESTED --> DENIED: patient rejects GRANTED --> EXPIRED: validity passes GRANTED --> REVOKED: patient revokes EXPIRED --> [*] DENIED --> [*] REVOKED --> [*]
- Request — HIU calls consent-request init with purpose, hiTypes, date range, and requested expiry.
- Notify — CM pushes the pending request to the patient's PHR app.
- Grant / Deny — the patient reviews; on grant the CM issues one artefact per HIP covered and notifies each HIP.
- Fetch — the HIU fetches granted artefacts and can then issue health information requests.
- Expiry / Revocation — the CM notifies both sides; the HIU must stop
using and erase the data per
dataEraseAt.
Obligations on the HIU
Granted consent is not ownership. Respect accessMode (VIEW vs STORE),
honour frequency limits, purge on dataEraseAt, and handle revocation
immediately. Certification tests check these behaviours.
Patient-initiated consents
Patients can also proactively share from their PHR app (self-initiated consent / subscription flows), and set auto-approval policies for trusted HIUs — your HIU should handle artefacts that arrive without a preceding request from your side.